High-R walls and where they fail

Step 4 and Step 5 airtightness results are decided less by insulation thickness than by four joints. The details that matter.

InoBuilt Construction · · 2 min read

High-R walls and where they fail

Step 4 allows up to 1.5 ACH50. Step 5 allows up to 1.0. The result is decided less by insulation thickness than by four joints:

High-R walls and where they fail: Section
  1. Wall to roof. Raised-heel trusses keep full insulation depth at the eaves and give the air barrier room to turn the corner.
  2. Slab edge. Insulation wraps the foundation and meets the wall insulation, so the floor perimeter is not a cold line.
  3. Windows. Rough openings sealed to the air barrier, detailed before the windows arrive.
  4. Penetrations. Fewer pipes, ducts and wires through the barrier, and each one planned.
High-R walls and where they fail: Eave

Two design choices sit upstream of all four. Exterior continuous insulation versus double-stud (warmer sheathing and better drying versus a deeper cavity with more moisture risk), and solar control (SHGC and overhangs by orientation, because a tight house holds heat).

Have a lot in mind?

Send the address and we’ll run a free desktop check of what it appears to allow, within two business days.

Request a lot check →
Sources

BC Building Code, Part 9 energy step requirements (ACH50 limits by step). Other points are general building-science practice.

General information, checked Nov 9, 2026. Rules change and differ by municipality; confirm for your lot before relying on it. Not legal, tax or financial advice.

ShareLinkedIn